Jc660ca Thin Film Absolute Pressure Transmitter, Anti-Explosion Diaphragm Pressure Sensor

Product Details
Customization: Available
Type: Piezoresistive Pressure Sensor
Component: Mechanical Structure Type
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (22)
  • Jc660ca Thin Film Absolute Pressure Transmitter, Anti-Explosion Diaphragm Pressure Sensor
  • Jc660ca Thin Film Absolute Pressure Transmitter, Anti-Explosion Diaphragm Pressure Sensor
  • Jc660ca Thin Film Absolute Pressure Transmitter, Anti-Explosion Diaphragm Pressure Sensor
  • Jc660ca Thin Film Absolute Pressure Transmitter, Anti-Explosion Diaphragm Pressure Sensor
  • Jc660ca Thin Film Absolute Pressure Transmitter, Anti-Explosion Diaphragm Pressure Sensor
  • Jc660ca Thin Film Absolute Pressure Transmitter, Anti-Explosion Diaphragm Pressure Sensor
Find Similar Products

Basic Info.

Model NO.
JC660CA
For
Diffused Silicon Pressure Transmitter
Output Signal Type
Analog Type
Production Process
Integration
Material
Stainless Steel
Wiring Type
Four-Wire
Measuring Medium
Gas Liquid Steam
IP Rating
IP67
Certification
CE
Customized
Customized
Transport Package
Standard Exporting Carton
Trademark
JC
Origin
Nanjing, China
Production Capacity
5000 Pieces Per Month

Product Description


Jc660ca Thin Film Absolute Pressure Transmitter Overview:

JC660 series of thin film absolute pressure transmitter is specially designed for high-explosion dangerous site. It can provide stable and accurate measurement at an absolute pressure, gauge pressure and differential pressure of liquid or gas medium from -100KPa to 200MPa. It welds the existing multi -crystalline silicon film sensing element of HELM with the enclosure using welding technology and can be customized rapidly according to the regulations to meet the individualized needs of different users. With built-in amplification circuit and diversified structural forms, it can be equipped with M 20 x 1.5 or G1 / 2 internal thread explosion-proof flexible tube connector. Featured by good performance, small size and flexible design, JC660 series thin film absolute pressure transmitter has the advantages of a very high ratio of performance to cost and long service life compared with traditional explosion-proof transducers. It is widely used in oilfield, mining well, chemical, electric power, boiler, natural gas and other fields.

JC660-E type pressure sensor  is an intrinsically safe explosion-proof pressure transducer, with explosion- proof marking of Ex iaII CT6 and explosion-proof conformity certificate number of CNEx07.0988. It boasts stable and reliable performance supporting the use of repetitive-use type safety energy limiter or safety barrier.

JC660-D type pressure sensor is a flameproof pressure transducer, with explosion-proof marking of Ex dIICT6 and explosion-proof conformity certificate number of CNEx08.2405. JC660-ED type is an intrinsically safe flameproof pressure transducer, with explosion -proof marking of Ex iaII CT6 and Ex dII CT6. It is safe and reliable and simple and convenient to operate, without the installation of safety barrier when installed and used. 


Jc660ca Thin Film Absolute Pressure Transmitter Features:

* Intrinsically safe and flameproof certification: Ex iaII CT6, Ex dII CT6
* Measuring range: -100KPa~0~200Pa...100KPa...200MPa 
* Gauge pressure, absolute pressure and differential pressure are available
* Explosion - proof design, safe and reliable 
* Adoption of explosion-proof genuine HELM multi - crystalline silicon film chip, with stable and reliable performance and long service life
* Reverse polarity and over-voltage protection of power supply
* Strong anti-interference and immunity to vibration and excellent long -term stability


Technical Parameters:
Measuring range -100KPa~0~200Pa...5KPa...200MPa
Overload capacity Two times FS pressure (1.1 times FS pressure for 100MPa product) 
Pressure type Gauge pressure, absolute pressure, differential pressure
Measured medium Gas or liquid compatible with 316 stainless steel
Overall accuracy(Non-linearity, repeatability, lagging) ±0.1%FS ±0.25%FS ±0.5%FS
Long-term stability Typical: ±0.1%FS/ year
Zero point temperature drift Typical: ±0.02%FS/ºC
Sensitivity temperature drift Typical: ±0.02%FS/ºC
Operating temperature -20 ~ 85ºC    
Compensation temperature -20 ~ 60ºC  
Range of power supply 12~36VDC (24VDC generally)
Signal output 4~20mA/1~5VDC/0~5VDC
Load resistance ≤(U-12)/0.02  Ω
Insulation resistance ≥2000MΩ(testing condition100VDC)
Resolution Infinite small (theoretical) 1 / 100000 (general) 
Response time ≤1 ms
Influence of vibration Within mechanical vibration frequency 20Hz ~ 1000Hz, change of output is less 
than 0.1% FS 
Weight Approx. 0.5kg

Ordering Information:
JC660CA Thin Film Absolute Pressure Transmitter
  Pressure type Gauge pressure; absolute pressure (A); differential pressure (D)
  Range  (0~ X MPa) Measuring range
  Code Overall accuracy (linearity + repeatability + lagging)
1 ±0.5%FS
2 ±0.25%FS
3 ±0.1%FS
  Code  Signal Output
A1 4~20mA  
V1 1~5V DC         
V2 0~5V DC         
V3 0.5~4.5V DC 
  Code Additional functions
F1 M20x1.5 external thread
F2 G1/4 external thread
F0 Special
W1 Cable type (IP67, 2m)
W2 HSM socket type (IP65, DIN43650)
W3 Outline drawing (I)
W4 Outline drawing (II)
W0 Special 
L1 Pointer scale (0 ~ 100%) display
L2 4LCD display
L3 4LED display
P Flush diaphragm
Intrinsically safe Ex iaII CT5
D       Flameproof Ex dII CT6
JC660CA   -1   -A1   -F1   -W3   -D        Thin Film Absolute Pressure Transmitter

Tips for Type Selection
* The measured medium shall be compatible with the material contacting with the product. 
* The code E, an additional function code for selection, namely, intrinsically safe explosion-proof Ex iaIICT6 must be power supplied via safety barrier.
* The code D, an additional functional code for selection, namely, flameproof Ex dIICT6 is preferably provided with explosion-proof flexible hose for the electrical power cable connected at the rear side.
* The options W1 and W2 are general structural encapsulation and only used for HM60 -E intrinsically safe explosion-proof pressure transducer.
* It is unnecessary to install safety barrier on HM60 - ED intrinsically safe flameproof pressure transducer during system use.
* Please contact us for other special requirements and clearly indicate them in the order.

About Jiucheng

Qualification and Certificate:



Product Packaging:
We choose cartons and protective pads that can be recycled. This will maximize the protection of our products from damage during transportation.

Product Transportation:
We only choose the global express service providers. We will deliver the goods to you at the most efficient speed.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier