Jc627g Vacuum, Absolute Gas and Liquid Pressure Sensor

Product Details
Customization: Available
Manufacturer/Factory & Trading Company
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (22)
  • Jc627g Vacuum, Absolute Gas and Liquid Pressure Sensor
  • Jc627g Vacuum, Absolute Gas and Liquid Pressure Sensor
  • Jc627g Vacuum, Absolute Gas and Liquid Pressure Sensor
  • Jc627g Vacuum, Absolute Gas and Liquid Pressure Sensor
  • Jc627g Vacuum, Absolute Gas and Liquid Pressure Sensor
  • Jc627g Vacuum, Absolute Gas and Liquid Pressure Sensor
Find Similar Products

Basic Info.

Model NO.
JC627G
Production Capacity
5000 Pieces Per Month

Product Description


JC627G Vacuum Pressure Sensor Overview:

As a new series product specially used for vacuum measurement and control, JC627 vacuum pressure sensor has completely solved the problem of difficult vacuum measurement. This series product has three specifications, i.e. JC627G negative pressure transducer, JC627A absolute pressure transducer and JC627CA capacitor thin-film absolute pressure transducer, which have widely been used in such fields as pharmaceutical, medical equipment, airspace and aerospace, scientific research, leakage detection and completed automation equipment fields.
By use of a mono-crystalline silicon thick-film sensor, JC627G negative pressure transducer is equipped with a high-accuracy signal processing circuit, with stable and reliable performance, which has solved such disadvantages of domestic diffused silicon-type negative pressure vacuum products as unstable signal and short service life. Normal ranges include 0 ~ 100KPa and 0 ~ 50KPa, etc.

JC627G Vacuum Pressure Sensor Features:
* Fully provided with foreign high- accuracy sensing elements, with the maximum accuracy of up to 0.1% FS
* Continuously operable for a long time, with good long- term stability
* Applicable for measuring corrosive medium according to special requirements
* Strong overloading resistibility.Fast response. Stable and reliable performance
* Applicable for hazardous areas, with intrinsically safe explosion-proof type Ex ia II CT5
* With structural diversification, the product can be designed in an individualized manner as per customers' special requirements

Technical Parameters:
Measuring media The gas or liquid compatible with 316 stainless steel
Pressure type Negative gauge pressure (G), silicon- type absolute pressure (A), capacitor thin-film absolute pressure (CA)
Overload capacity 2 times at negative gauge pressure; 10 times to one hundred times at micro-range absolute pressure
Measuring range Negative gauge pressure: 0~-5KPa ..-50KPa…-100KPa
Silicon-type absolute pressure: 0~5KPa…..10KPa …20KPa…100KPa…200KPa…1MPa
Capacitor thin-film absolute pressure: 0.02Pa~200Pa,1Pa~1KPa
Overall accuracy (nonlinearity + 
repeatability+ hysteresis)
±0.1%FS ±0.25%FS ±0.5%FS
Long-term stability Typical:±0.1%FS/ year Maximum:±0.15%FS/year
Zero temperature drift Typical:±0.01%FS/ºC Maximum:±0.15%FS/ºC
Sensitivity temperature drift Typical:±0.01%FS/ºC Maximum:±0.15%FS/ºC
Range of operating temperature -20~ 80ºC 
Range of compensation temperature -10 ~ 60ºC  
Ambient temperature -20 ~ 80ºC
Range of power supply 12~36VDC(generally 24VDC)
Signal output 4~20mA/1~5VDC/0~5VDC
Load resistance ≤(U-12)/0.02  Ω
Resolution Infinitely small (theoretical),,1/100000(normal)
Enclosure protection class Plug type(IP65); cable type (IP67)
Safety and explosion protection Ex iaII CT5
Vibration error ≤±0.01%FS(Axes X, Y and Z, 200Hz/g)
Response time ≤2 ms

Ordering Information:
JC627G vacuum pressure sensor
  Pressure type Negative gauge pressure (G),  silicon- type absolute pressure (A), capacitor thin-film absolute pressure (CA)
  Measuring range 0~X KPa or 0~X Mpa
  Code Overall accuracy (linearity + repeatability+ hysteresis)
1 ±0.5%FS  
2 ±0.25%FS  
3 ±0.1%FS  
  Code Signal output
A1 4~20mA(12~36V DC)
V1 1~5V DC(12~36V DC)
V2 0~5V DC (12~36V DC)      
V3 0~10V DC(24V DC)
  Code Additional functions
F1 M20x1.5  external thread
F2 G1/4 external thread
F3  Clamped type
F0 Special
W1 Cable type (IP67,2m)
W2 Socket type (IP65,DIN43650)
W3  Aviation plug
P Flush-diaphragm type
E Intrinsically safe explosion-proof type
Ex iaIICT5
JC627A(0~10KPa)   -1    -A1    -F1    -W2        vacuum pressure sensor

Tips for Type Selection
* The medium to be measured shall be compatible with the material contacting with the product.
* As an additional function code for type selection, the code "E" for intrinsically safe explosion-proof type Ex iaIICT5 denotes that power source must be supplied via safety barrier.
* For other special requirements, please discuss with us and clearly indicate them in the order.


About Jiucheng

Qualification and Certificate:



Product Packaging:
We choose cartons and protective pads that can be recycled. This will maximize the protection of our products from damage during transportation.


Product Transportation:
We only choose the global express service providers. We will deliver the goods to you at the most efficient speed.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier