Basic Info.
Model NO.
Pressure Transducer UC2
Type
Normal Pressure Transmitter
Structure Type
Diffused Silicon Pressure Transmitter
Transport Package
Carton Box
Product Description
Pressure transducer UC2 ApplicationPressure transducer e.g. for use in medical and laboratory-specific measuring technology, shipbuilding and hydrostatic level measurement.
Dimensions: 1.basic module ø21.9x26; 2.basic module ø21.9x18,5; 3.basic module ø21.9x30Pressure transducer UC2 Benefits:* Basic ceramic material Aluminum
oxide ceramic Al2O3
(Measuring cells 1 bar purity 99,7 %)
(Measuring cells 2 bar purity 96 %)
* High overload resistance
* Long-term stability
* Corrosion-resistant
* Finely graduated measuring ranges:
0 to 200 mbar to 0 to 20 bar gauge pressure or absolute pressure
* Special measuring ranges available on request, e.g. 0 to 100 mbar gauge pressure
* Small physical size from Ø21.9 mm
* Flexibly adapted to customer-specific
* requirements
* Housing made from various materials
* Various seal materials
* Output signal 0.5 to 4.5 V or 4 to 20 mA
Pressure transducer UC2 Measuring Principle:A capacitive ceramic sensor element is at the core of the UC2 transducer.
Its Al2O3 basic material is ceramic that is highly resistant against many aggressive gases and liquids. Two cylindrical ceramic components (diaphragm and meter body) are bonded to form a high-strength, hermetically sealed pressure sensor element. With absolute pressure sensors, the vacuum of 3.0 x 10-6 mbar created in the production process between the process isolating diaphragm and the meter body remains permanently. This permits pressure measurements relative to the vacuum. With gauge pressure sensors, the back of the process isolating diaphragm is vented, i.e. this sensor measures the gauge pressure relative to the atmospheric pressure.
Electrically, the sensor element represents a plate capacitor whose capacitance change is the dimension for the pressure change. The capacitive measuring process satisfies the highest requirements concerning resolution and reproducibility. Together with the hysteresis-free behavior of the material Al O , it is the basis for the excellent specifications of the transducer. In addition, the sensor element is a dry measuring cell, i.e. there is no separating diaphragm or filling fluid which could influence the measurement. A further advantage of the capacitive ceramic sensor is its high overload resistance.After removal of the overload, the process isolating diaphragm returns to the initial position without any damage or hysteresis.
InputMeasured variable | Gauge pressure or absolute pressure |
Measuring range | Gauge pressure measurement: 0.2 to 20 bar |
Absolute pressure measurement: 0.2 to 20 bar |
Special measuring ranges available on request (e.g. 0 to 100 mbar absolut pressure) See also "Ordering information" chapter ä 11. |
OutputOutput signal | Voltage output 0.5 to 4.5 V ratiometric |
Current output 4 to 20 mA |
Load | Voltage output: 10 k or 300 pF |
Current output: RB = (US -12 V)/0.02 A (US = supply voltage) |
Supply voltage* Voltage output: 4.5 to 5.5 V DC stabilized
Ratiometric signal: proportional effect on lower range-value and span
No effect on linearity and temperature compensation
* Current output: 12 to 30 V DC
The permitted voltage range is limited for devices with an explosion protection certificate.
Observe therelated Safety Instructions XA513P.
Current consumption* Voltage output: max. 2 mA with a supply voltage of 5 V, with reverse polarity protection
* Current output: max. 23 mA, with reverse polarity protection
Performance characteristics:Reference operating conditions | As per DIN IEC 60770 Tu = 25 °C (77 °F), humidity 45 to 75 %, ambient air pressure 860 to 1060 mbar, compensated temperature range: -20 to 80 °C |
Zero point deviation | Voltage output Max. ±1 % of span | Current output Max. ±0.3 % of span With extended specification and small measuring ranges <0.3 bar, max. ±0.5 % of span. |
Span deviation | Voltage output Max. ±1 % of span | Current output Max. ±0,3 % of span With extended specification and small measuring ranges <0.3 bar, max. ±0.5 % of span. |
Maximum measured error | Non-linearity + hysteresis + non-reproducibility: max. ± 0.25 % of span |
Rise time (T90) | Approx. 5 ms |
Settling time (T99) | Max. 10 ms |
Long-term stability | Max. 0.15 % of span per year |
Thermal change of the zero output within the compensated temperature range | Voltage output Max. ±0,75 % of span With extended specification ±1 % of span | Current output Max. ±1 % of span With extended specification ±1.25 % of span. |
Thermal span change within the compensated temperature range | Voltage output: max. ± 0.5 % of span. With measuring ranges < 0.4 bar, the value increases to ± 0.8 % of span. With extended specification ± 1 % of span Current output: max. ± 1 %. With extended specification ± 1.25 % of span Voltage output |
Max. ±0,5 % of span With measuring ranges <0,4 bar, the value increases to ±0,8 % of span. With extended specification ±1 % of span. | Max. ±1 % of span With measuring ranges <0,4 bar, the value increases to ±1.25 % of span. With extended specification ±1.25 % of span. |
Current consumption |
Orientation | Random Observe position-dependent zero point shift with small pressure ranges (1 bar). |
Operating conditions: Environment |
Ambient temperature range | -20 to +80 °C The permitted temperature range is limited for devices with an explosion protection certificate. Observe the related Safety Instructions XA513P. |
Storage temperature | -40 to +80 °C |
Degree of protection | Depends on housing (IP 68 possible) |
Climate class | 4K4H as per DIN EN 60721-3 (can be achieved with closed pressure transducers) |
Shock resistance | 15 g as per DIN EN 60068-2-29 (6 ms) |
Electromagnetic compatibility | The following applies for complete devices with a current output: Interference emission to EN 61326 Class B equipment. Interference immunity to EN 61326, Appendix A (Industrial) |
Operating conditions (process) |
Process temperature limits | -20 to +80 °C Note the temperature limits of the applied process seal (see chapter "Material" ä 9) |
Overload resistance | Overload limit: see chapter "Ordering information" ä 11. Overload effect: negligible |
Vacuum resistance | Vacuum-resistant |
Material* Process isolating Diaphragm
Aluminum oxide ceramic Al2O3
(Measuring cells 1 bar purity 99,7 %)
(Measuring cells 2 bar purity 96 %)
* Process seal
FKM: Viton, temperature range 20 to +80 °C
FFKM: temperature range 0 to +80 °C
EPDM: temperature range 20 to +80 °C; FDA number 21 CFR 177.2600
HNBR: temperature range 20 to +80 °C
* Housing
316L (1.4404) standard
Other materials on request.
Certificates and approvals |
CE mark | For complete devices with a current output: The device meets the legal requirements of the EC directives. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. |
Pressure Equipment Directive(PED) | This measuring device corresponds to Article 3 (3) of the EC directive 97/23/EC (Pressure Equipment Directive) and has been designed and manufactured according to good engineering practice. |
External standards and guidelines | DIN EN 60770 (IEC 60770): Transmitter for controlling and regulating in industrial process engineering systems |
DIN EN 61003-1, Ed.: 1993-12 Industrial process control systems; Instruments with analog inputs and two-or multi-state outputs; Part 1: Methods of evaluating operating performance. |
DIN 16086 Electrical pressure measuring instruments - Pressure transmitters, pressure measuring instruments |
IEC 60529 Degrees of protection provided by enclosures (IP code). |
EN 61326: Electrical equipment for measurement, control and laboratory use - EMC requirements. |
Ordering Information:Pressure transducer UC2 |
| 10 | Sensor nominal range; Overload |
| B | 0 to 200 mbar /20 kPa/3 psi absolute; 4 bar/400 kPa/ 60 psi 1) |
C | 0 to 400 mbar /40 kPa/6 psi absolute; 4 bar/400 kPa/ 60 psi ) |
D | 0 to 1 bar /100 kPa/15 psi absolute; 10 bar/1 MPa/ 150 psi |
E | 0 to 2 bar /200 kPa/30 psi absolute; 15 bar/1.5 MPa/ 225 psi |
F | 0 to 4 bar /400 kPa/60 psi absolute; 25 bar/2.5 MPa/ 375 psi |
G | 0 to 10 bar /1 MPa/150 psi absolute; 40 bar/4 MPa/ 600 psi |
H | 0 to 20 bar /2 MPa/300 psi absolute; 40 bar/4 MPa/ 600 psi |
M | 0 to 200 mbar /20 kPa/3 psi relative; 5 bar/500 kPa/ 75 psi |
N | 0 to 400 mbar /40 kPa/6 psi relative; 6 bar/600 kPa/ 90 psi |
O | 0 to 1 bar /100 kPa/15 psi relative; 10 bar/1 MPa/ 150 psi |
P | 0 to 2 bar /200 kPa/30 psi relative; 15 bar/1.5 MPa/ 225 psi |
R | 0 to 4 bar /400 kPa/60 psi relative; 25 bar/2.5 MPa/ 375 psi |
S | 0 to 10 bar /1 MPa/150 psi relative; 40 bar/4 MPa/ 600 psi |
T | 0 to 20 bar /2 MPa/300 psi relative; 40 bar/4 MPa/ 600 psi |
20 | Calibration; Unit |
| A | See additional specification (special measuring ranges with extended specifications) |
1 | Sensor nominal range; mbar/bar |
2 | Sensor nominal range; kPa/MPa |
3 | Sensor nominal range; psi |
30 | Output |
| B | 4 to 20 mA |
C | 0.5 to 4.5 V + power supply 5 V |
40 | Sensor seal |
| 0 | FKM Viton |
1 | HNBR |
7 | FFKM 495 |
8 | EPDM-E7502, FDA |
50 | | Process connection |
| AA | Basic module ø21.9x26; 316L |
AB | Basic module ø21.9x30; 316L |
AC | Basic module ø21.9x18.5; 316L |
UC2 - 10 20 30 | 40 50 | 60 | 70 | 80 | 90 | 100 110 |
Other measuring ranges and special versions available on request.
Additional documentationOperating instructions
Safety instructions
BA902P/00/A2
Certificate/explosion protection
ATEX II 1/2 G Ex ia IIC T6 Ga/Gb
ATEX II 1/2 D Ex ia IIIC T 90 °C Da/Db
Documentation
- XA513P
Nanjing Jiucheng Technology Co.,Limited. as the industry leader of China's piezoresistive pressure sensor, has decades of experience in designing, developing and manufacturing diffusion silicon, ceramic pressure sensors and transmitters, adhering to the spirit of technological innovation and management innovation. Concentrate on process technology, pay attention to service quality, and provide customers with various special sensors and detection solutions. The product covers 6 categories: pressure core, pressure transmitter, liquid level transmitter, differential pressure transmitter, temperature transmitter, intelligent pressure switch and pressure gauge, dozens of series, hundreds of specifications, Widely used in petroleum, chemical, power station, automation equipment manufacturing, medical, pharmaceutical, food and other industries.
Adhering to the long-term tradition and continuous innovation, we continue to focus on technology development, product scale production and technical services in the measurement and control industry. Adhering to the successful strategy of "active, development and transcendence" of modern enterprises, Jiucheng Company and China's pressure measurement and control industry develop together and improve with the international advanced technology level. Sincerely hope to cooperate with friends all over the world!
Address:
Room 612, Building 1, Business Space Plaza, No. 2, Jinyuan Road, Dongshan Street, Jiangning District, Nanjing, Jiangsu, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Auto, Motorcycle Parts & Accessories, Consumer Electronics, Electrical & Electronics, Industrial Equipment & Components, Instruments & Meters
Management System Certification:
ISO 9001
Company Introduction:
Established in 2006, Nanjing Helm Sci-tech Co., Ltd. (Nanjing Jiucheng technology Co., Ltd) is specialized in R&D and production of pressure measuring and controlling instruments. It has introduced the internationally advanced production technology, equipment and process as well as strict product quality standards and ODM cooperation concept to China, so as to manufacture and sell JC pressure / differential pressure / liquid level sensors and transducers in mainland China.
Our products have been fallen into six categories totaling hundreds of specifications in dozens of series. Main products include: High-accuracy Pressure Sensor, General-purpose Pressure transducer, Liquid Level transducer, Anti-lightning/Anti-corrosive Liquid Level transducer, Special Pressure transducer for Air Conditioner, Refrigeration and Compressor, Special Pressure transducer for Oilfield and Mining Well, Economical Pressure Sensor and transducer, Ceramic Capacitor Pressure transducer, Vacuum Pressure transducer, Sapphire Pressure transducer, Digital Pressure transducer, Micro Differential Pressure / Air Pressure transducer, Intelligent Digital Pressure Gauge, Intelligent Digital Pressure Switch, Anti-corrosive Pressure transducer, Anti-explosive Pressure transducer, Hygienically Flat-membrane Pressure transducer, High-temperature Pressure transducer, High-frequency Pressure transducer, Micro Pressure transducer, Integrated Temperature transducer, and Capacitance Pressure transducer.