JC621 Fire Water Tank Liquid Level Transmitter

Product Details
Customization: Available
Type: Silicon Piezoresistive Type
Structure Design: Input Type
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
1001~2000 square meters
  • JC621 Fire Water Tank Liquid Level Transmitter
  • JC621 Fire Water Tank Liquid Level Transmitter
  • JC621 Fire Water Tank Liquid Level Transmitter
  • JC621 Fire Water Tank Liquid Level Transmitter
  • JC621 Fire Water Tank Liquid Level Transmitter
  • JC621 Fire Water Tank Liquid Level Transmitter
Find Similar Products

Basic Info.

Model NO.
JC621
IP Rating
IP68
Certification
CE
Customized
Customized
Measuring Range (Fs)
0~0.5m…200mh2o or 0~5kpa…2MPa
Overall Accuracy
±0.25%Fs~±1%Fs
Long-Term Stability
±0.1%Fs/Year~±0.2%Fs/Year
Operating Temperature Range
Integrated: -20ºC~70ºC
Compensation Temperature Range
Integrated:-10ºC~55ºC
Zero-Point Temperature Drift
±0.02%Fs/ºC~±0.05%Fs/ºC
Full-Scale Temperature Drift
±0.02%Fs/ºC~±0.05%Fs/ºC
Range of Power Supply
12~36VDC
Signal Output
4~20mA/1~5VDC/ 0~5VDC
Transport Package
Standard Exporting Carton
Trademark
JC
Origin
Nanjing, China
Production Capacity
5000 Pieces Per Month

Product Description


JC621 Fire Water Tank Liquid Level Transmitter Overview:
The measurement of water or liquid level using hydrostatic equilibrium system is an important application of pressure sensors. The high-sensitivity silicon piezoresistive sensitive element fabricated with micromachining technology is the critical component of the liquid level transducer, supported with the special cable provided with an air tube as well as special water-tightness technology, which not only ensures the water tightness of immersion transducers, but also makes the reference pressure chamber connect with the ambient atmosphere, so as to attain accurate measurement results and excellent stability. JC621 fire water tank liquid level transmitter adopts the internationally advanced dry ceramic capacitive sensor or temperature-compensating isolation diaphragm diffused silicon pressure sensor as a sensing element to greatly enhance operating performance of the product. It can be extensively used for the measurement and control of water and liquid levels in petroleum, chemical, power generation plant, urban water supply & drainage and hydrologic exploration fields, etc.. 

JC621 Fire Water Tank Liquid Level TransmitterJC621 Fire Water Tank Liquid Level Transmitter
JC621 Fire Water Tank Liquid Level Transmitter Features:
* Split structure: The section of the sensor thrown into the liquid is of fully-sealed stainless steel structure, wherein the enclosure of the electronic circuit is of cast aluminum structure for easy alignment & adjustment and wiring.
* Integrated structure: Both the sensor and the amplified circuit are provided in the fully-sealed enclosure made of stainless steel, without external alignment and adjustment.
* The enclosure of the sensor is designed with IP68 and the junction box is designed with IP65.
* This product takes the high-performance pressure sensor as the measuring element, with high accuracy, small dimensions, easy operation, strong antijamming capability, high reliability, good stability, high sensitivity, water resistance and anti-condensation. 
* The product is of free maintenance, as well as easy installation and commissioning. It can be directly thrown into the water to measure the height of liquid level from the transducer end to the liquid surface.

As shown in Figure 1, for installation in the water tank, water tower and other static water, generally the sensing end is directly thrown into the bottom of the water tank as far away from the pump and valve position as possible. The wiring section of the transducer is provided within the junction box, with the outgoing line pointing downward, to prevent water from penetrating into the airway tube of the air-guiding cable. Meanwhile, remember not to block the airway tube.

As shown in Figure 2, for installation in the water dam, water well and other flowing water, a steel tube with an inner diameter of approximately φ45mm is generally inserted into the water channel, where some small holes shall be drilled at the same height opposite to the water flow direction so that water can smoothly flow into the tube. The wiring section of the transducer is provided within the junction box, with the outgoing line pointing downward, to prevent water from penetrating into the airway tube of the air-guiding cable. Meanwhile, remember not to block the airway tube.

Figure 3 shows threaded or flanged connection of the split liquid level transducer in the open-hole vessel, wherein thread size or flange size are G 1 / 2 and DN20 respectively or customized.

Technical Parameters:
Measuring range (FS) 0~0.5m...200mH2O or 0~5KPa…2MPa
Permissible overpressure Two times of full-scale pressure
Measuring media The liquid compatible with 316 stainless steel
(Corrosion-proof type can be selected under special conditions)
Overall accuracy ±0.25%FS ±0.5%FS ±1%FS
Long-term stability Typical:±0.1%FS/year Maximum:±0.2%FS/year
Operating temperature range Integrated:-20ºC~70ºC Split (plug-in):-20ºC~80ºC
Compensation temperature range Integrated:-10ºC~55ºC Split (plug-in):-10ºC~70ºC
Zero-point temperature drift Typical:±0.02%FS/ºC Maximum:±0.05%FS/ºC
Full-scale temperature drift Typical:±0.02%FS/ºC Maximum:±0.05%FS/ºC
Range of power supply 12~36VDC(generally 24VDC)
Signal output 4~20mA/1~5VDC/O~5VDC
Load resistance ≤(U-10)/0.02Ω
Structural material Enclosure:stainless steel Cr18Ni9Ni Diaphragm:stainless steel 316L
Sealing:fluoro rubber Cable:Φ7.2mm special PVC cable
Insulation resistance 100MQ,50VDC
Protection class Enclosure protection class IP68
Safety and explosion protection Ex ia ll CT5
Response time ≤2 ms
Weight Approx.250g
Resolution Infinitely small(theoretic),1/100000(normal)

Ordering Information:
JC621 Throw-in Type Liquid Level Transducer
  Measuring range 0~X mH2O or 0~X KPa
  Code Structural form(maximum operating range)
C1 Integrated:0~200mH2O
C2 Split:0~10mH2O
C3 Plug-in:0~4 mH2O
 
Code
Overall accuracy (linearity +repeatability+hysteresis)
1.0%FS
0.4%FS

2

0.25%FS
  Code Signal output(standard power supply)
A1 4~20mA(12~36V     DC)
V1 1~5V DC(12~36V DC)
V2 0~5V   DC(12~36V   DC)
S1 RS485(5~9V DC)
  Code Additional functions
F1 G1/2 male thread(split and plug-in)
F2 DN20 flange(split and plug-in)
F0 Special
E
Intrinsically safe explosion-proof type Ex iallCT5
R Corrosion-proof type
JC621(0~10mH2O)-C1 -1 -A1 -E Throw-in Type Liquid Level Transducer

Tips for Type Selection
1. The medium to be measured shall be compatible with the material contacting with the product. Meanwhile, the density of the medium to be measured during measurement shall be indicated (except for water).
2. As an additional function code for type selection, the code "E" for intrinsically safe explosion-proof type Ex ia II CT5 denotes that power source must be supplied via safety barrier.
3. The length of cable shall be L = X m + 1m. Please indicate any extension (if needed) when placing an order.
4. To install the product in thunderous areas, select HM21F Anti-lightning Liquid Level Transducer when placing an order.
5. The corresponding relationship of 1m water columns with pressure under standard conditions (i.e.4ºC,g =9.80665m/s2):1mH2O=0.1kgf/cm2(Kgf  /cm²)=9.8kPa(KPa)
6. For other special requirements, please discuss with us and clearly indicate them in the order.
 