JC-UCS2 / UC2 Ceramic Capacitive Pressure Sensor

Product Details
Customization: Available
Type: Capacitive Pressure Sensor
For: Capacitive Pressure Transmitter
Manufacturer/Factory & Trading Company
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (22)
  • JC-UCS2 / UC2 Ceramic Capacitive Pressure Sensor
  • JC-UCS2 / UC2 Ceramic Capacitive Pressure Sensor
  • JC-UCS2 / UC2 Ceramic Capacitive Pressure Sensor
  • JC-UCS2 / UC2 Ceramic Capacitive Pressure Sensor
  • JC-UCS2 / UC2 Ceramic Capacitive Pressure Sensor
  • JC-UCS2 / UC2 Ceramic Capacitive Pressure Sensor
Find Similar Products

Basic Info.

Model NO.
Ucs2/UC2
Output Signal Type
Analog Type
Production Process
Ceramics
Material
Ceramics
Thread Type
Customized
Wiring Type
Customized
Measuring Medium
Gas or Liquid
IP Rating
IP65
Certification
ISO
Customized
Customized
Measuring range
Gauge pressure measurement 0.1 to 70 bar, absolute
Measured variable
Choice of gauge pressure or absolute pressure
Zero point
0.50V±0.05V;applies to the respective lower
Span
4.00V±0.05V
Transport Package
Standard Exporting Carton
Trademark
JC
Origin
Nanjing, China
Production Capacity
5000 Pieces Per Month

Product Description


JC-UCS2 / UC2 Capacitive Ceramic Pressure Sensor Measuring principle:
The Ceracore UCS2/UC2 basic material is Al2O3 (99.9 %), a highly resistant ceramic material for many aggressive gases and liquids. Cylindrical ceramic components (diaphragm, meter body) are bonded to form a high- strength, hermetically sealed pressure sensor element. With absolute pressure sensors, the vacuum of 3.0 x 10-6 mbar created in the production process between the diaphragm and the meter body remains permanently. This permits pressure measurements related to the vacuum. With gauge pressure sensors, the back of the diaphragm is vented, i.e. this sensor measures the gauge pressure relative to the atmospheric pressure. Electrically, the sensor element represents a plate capacitor whose capacitance change is the dimension for the pressure change. The capacitive measuring process satisfies the highest requirements concerning resolution and reproducibility. Together with the hysteresis-free behavior of the material Al2O3 , it is the basis for the excellent specifications of the sensor. In addition, the Ceracore UCS2/UC2 is a dry measuring cell, i.e. there is no separating diaphragm or filling fluid which could influence the measurement. A further advantage of the capacitive ceramic sensor is its high overload resistance. After removal of the overload, it returns to the initial position without any damage or hysteresis. 

JC-UCS2 / UC2 Ceramic Capacitive Pressure SensorJC-UCS2 / UC2 Ceramic Capacitive Pressure Sensor

Dry capacitive ceramic sensor
Basic ceramic material (99.9 % Al2O3)
* Extremely high overload limit
* Absolutely resistant to wear
* High temperature stability
* High long-term stability
* No hysteresis
* Corrosion-resistant

Active electronics
* Sensor-specific signal conditioning 
* High-accuracy pressure measurement with temperature stability


Technical Parameters:
Input Measured variable Choice of gauge pressure or absolute pressure
Measuring range Gauge pressure measurement 0.1 to 70 bar,absolute pressure measurement 0.2 to 70 bar
Output
(Values
dependent on
installation)
Zero point 0.50V±0.05V;applies to the respective lower range-value of the measuring range
Span 4.00V±0.05V
Characteristic curve linear;max.non-linearityδ0.2%of span
Load ε10k∧or  δ300 pF(with signal deviation <0.1%of span)
Rise time approx.1 ms
Switch-on time max.10 ms
Long-term stability max.0.1%of span per year
Output signal 0.5 to 4.5V
Power supply Supply voltage 5VDC stabilized,minimum 4.5V/maximum 5.5V
Influence of supply voltage:no influence on linearity /proportional on lower range-value
/proportional on span,no influence on temperature compensation
Current consumption Maximum 2 mA at a supply voltage of 5V
Operating
conditions:
Installation
Orientation Arbitrary.Operate the sensor system with the diaphragm pointing downwards.Otherwise
observe the position dependent zero point shift for small pressure ranges(δ 400 mbar).
Weight approx.17 to 23 g,depending on measuring range
Operating
conditions:
Environment
Ambient temperature range -40ºC to +125ºC(also applies to storage temperature)
Degree of protection IP 00 as per DIN 60529(IEC529);Climate class 3K3 DIN EN 60721-3-3
Operating
conditions:
Process
Reference operating conditions Gases and liquids
Media Diaphragm:aluminum  oxide  ceramic  Al2O3 (99.9%)
Material -40ºC to +125ºC,compensation temperature -20ºC to +80ºC
Thermal change Thermal change of the lower range-value in the compensation temperature range:max.
±0.75%of span,with extended specification±1%of span
Thermal change of output span in the compensation temperature range:max. ±0.5%of span.
With Measuring ranges d0.4 bar±0.8%of span,with extended specification±1%of span
Limiting medium pressure range Overload Overload limit:see"Ordering information"section,Overload influence:negligible
Vacuum resistance UCS2 with nominal value 400 mbar up to 70 bar:Ombar abs
UCS2 with nominal value 200 mbar:500 mbar abs (Version Min Ordering information)
UCS2 with nominal value 100 mbar:700 mbar abs (Version Lin Ordering information)


Ordering Information:
Sensor range;Overload (other measuring ranges and special versions on request)
A 0...100 mbar/10 kPa/1.5 psi absolute;4 bar/400 kPa/60 psi
B O to 200 mbar /20 kPa/3 psi absolute;6 bar/600 kPa/90 psi
C O to 400 mbar/40 kPa/6 psi absolute;6 bar/600 kPa/90 psi
D O to 1 bar/100 kPa/15 psi absolute;10 bar/1 MPa/150 psi
E O to 2 bar /200 kPa/30 psi absolute;18 bar/1.8 MPa/270 psi
F O to 4 bar /400 kPa/60 psi absolute;25 bar/2.5 MPa/375 psi
G 0 to 10 bar/1 MPa/150 psi absolute;40 bar/4 MPa/600 psi
H O to 20 bar /2 MPa/300 psi absolute;40 bar/4 MPa/600 psi
  O to 40 bar/4 MPa/600 psi absolute;60 bar/6 MPa/900 psi
J O to 70 bar /7 MPa/1050 psi absolute;105 bar/10.5 MPa/1575 psi
L O to 100 mbar/10 kPa/1.5 psi relative;4 bar/400 kPa/60 psi
M O to 200 mbar /20 kPa/3 psi relative;6 bar/600 kPa/90 psi
N O to 400 mbar /40 kPa/6 psi relative;6 bar/600 kPa/90 psi
O O to 1 bar/100 kPa/15 psi relative;10bar/1 MPa/150 psi
P O to 2 bar /200 kPa/30 psi relative;18 bar/1.8 MPa/270 psi
R O to 4 bar /400 kPa/60 psi relative;25 bar/5 MPa/375 psi
S O to 10 bar/1 MPa/150 psi relative;40 bar/4 MPa/600 psi
T 0 to 20 bar /2 MPa/300 psi relative;40 bar/4 MPa/600 psi
U O to 40 bar/4 MPa/600 psi relative;60 bar/6 MPa/900 psi
V O to 70 bar /7 MPa/1050 psi relative;105 bar/10.5 MPa/1575 psi