Customization: | Available |
---|---|
Type: | Normal Pressure Transmitter |
Structure Type: | Diffused Silicon Pressure Transmitter |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Measuring range | -100KPa~0~1KPa..20KPa….100MPa | |||
Overload capacity | Two times FS pressure((1.1 times FS pressure for 100MPa product) | |||
Pressure type | Gauge pressure or absolute pressure | |||
Measured medium | Gas or liquid compatible with 316 stainless steel | |||
Overall accuracy | ±0.1%FS | ±0.25%FS | ±0.5%FS | |
Intrinsic frequency | 150KHz~700KHz | 500KHz~1MHz | 1MHz~2MHz | |
Band width of transducer | 0~1KHz~3KHz | 0~20KHz | 0~200KHz | |
Rise time | 0~0.2mS~75μS | 0~12μS | 0~1μS | |
Long-term stability | Typical:±0.1%FS/year | Maximum:±0.2%FS/year | ||
Operating temperature | -40ºC~85ºC generally | -10ºC~250ºC specially | ||
Zero point temperature drift | Typical:±0.02%FS/ºC | Maximum:±0.05%FS/ºC | ||
Sensitivity temperature drift | Typical:±0.02%FS/ºC | Maximum:±0.05%FS/ºC | ||
Range of power supply | 12~36VDC(24VDC generally) | ±15VDC standard switching power supply | ||
Signal output | 4~20mA/1~5V DC/0~5V DC | |||
Load resistance | ≤(U-12)/0.02Ω | |||
Enclosure protection degree | Plug-in type (IP65);cable type (IP67) | |||
Vibration error | ≤±0.01%FS(Axles X,Y,Z,200Hz/g) | |||
Port and enclosure | Stainless steel 1Cr18Ni9Ti | |||
O-ring | Fluo rubber | |||
Sensor diaphragm | Stainless steel 316L or mono-crystalline silicon | |||
Safe explosion-proof | Exia IICT6 | |||
Insulation resistance | 100MQ,500V DC | |||
Resolution | Infinite small(theoretical)1/100000(general) |
JC690 | High-frequency Dynamic Pressure Transducer | ||||||
Code | Pressure type | ||||||
G | Gauge pressure(G,may not be indicated) | ||||||
A | Absolute pressure(A) | ||||||
Range | (0~X KPa or MPa) Measuring Range | ||||||
Code | Band width of transducer | ||||||
H1 | 0~1KHz~3KHz | ||||||
H2 | 0~20KHz | ||||||
H3 | 0~200KHz | ||||||
Code | Overall accuracy(linear +repeatability +lagging) | ||||||
1 | ±0.5%FS | ||||||
2 | ±0.25%FS | ||||||
3 | ±0.1%FS | ||||||
Code | Signal Output | ||||||
A1 | 4~20mA | ||||||
V1 | 1~5V DC | ||||||
V2 | 0~5V DC | ||||||
Code | Additional functions | ||||||
F1 | M20x1.5 external thread | ||||||
F2 | G1/4 external thread | ||||||
F0 | Special | ||||||
W1 | Cable type (IP67,2m) | ||||||
W2 | Socket type(IP65,DIN 43650) | ||||||
P | Flush diaphragm | ||||||
E | Intrinsically safe explosion-proof type ExiallCT5 | ||||||
T1 | Free field(specially used for blasting) | ||||||
T2 | High -temperature resistant type:Up to 250 ºC for balanced use,Up to 2000 ºC for transient use |
||||||
JC690(0~500KPa)-H1-1-V2-F1-W1-E -T2 High-frequency Dynamic Pressure Transducer |
Model example: JC90G010BA1F2W2
(JC90 High-Frequency Dynamic Response Pressure Transmitter; Range 0~1MPa Gauge; Output 4~20mA; Accuracy 0.5% typical; Power Supply 9~30VDC;Pressure Connection G1/4 male thread; Electrical Connection Hessman plug; Special instruction: 010B=10bar G/A, G/A stands for gauge and absolute pressure, G gauge, A absolute)
Remarks: It can be customized if the order quantity exceeds a certain amount. Please contact the sales engineers for details.