Basic Info.
Overall Accuracy
±0.25~±1%Fs
Long-Term Stability
±0.1~±0.2%Fs/Year
Zero Temperature Drift
±0.02~±0.05%Fs/ºC
Sensitivity Temperature Drift
±0.02~±0.05%Fs/ºC
Range of Power Supply
12~36VDC
Load Resistance
≤(U-12)/0.02Ω
Insulation Resistance
100mΩ,50VDC
Safety and Explosion Protection
Ex Iaii CT5
Product Description
JC621F Industry Anti-Lightning Water Level Sensor Overview:JC621F industry anti-lightning water level sensor is used to measure the liquid level using the principle that the liquid static pressure is directly proportionate to the liquid height. By use of foreign advanced silicon piezoresistive sensitive elements, supported with patented lightning protection devices, this series of products is specially designed for thunderous areas in Southern China, and is applicable for liquid level measurement of rivers, lakes, reservoirs and head water tanks, particularly of the hydrology and water conservancy of strong thunderous areas in Southern China and high mountain regions in Northern China. It has been successfully applied in many hydrographic industries in China.JC621F Industry Anti-Lightning Water Level Sensor Features:* With high sensitivity, fast response and high accuracy of measurement, the high-quality sensor can accurately reflect subtle changes in dynamic or static liquid level.
* Provided with lightning system and intrinsically safe explosion-proof capacity, it is applicable to all kinds of hazardous sites.
* 12V battery can be used to supply power under special conditions, so as to solve the problem of field power supply.
* Easy installation, convenient operation and strong interchangeability
* Fine and unique zero point, temperature drift and non-linear compensation ensure good accuracy and long-term stability of the instrument within the scope of working conditions.As shown in Figure 1, for installation in the water tank, water tower and other static water, generally the sensing end is directly thrown into the bottom of the water tank as far away from the pump and valve position as possible. The wiring section of the transducer is provided within the junction box, with the outgoing line pointing downward, to prevent water from penetrating into the airway tube of the air-guiding cable. Meanwhile, remember not to block the airway tube.
As shown in Figure 2, for installation in the water dam, water well and other flowing water, a steel tube with an inner diameter of approximately φ45mm is generally inserted into the water channel, where some small holes shall be drilled at the same height opposite to the water flow direction so that water can smoothly flow into the tube. The wiring section of the transducer is provided within the junction box, with the outgoing line pointing downward, to prevent water from penetrating into the airway tube of the air-guiding cable. Meanwhile, remember not to block the airway tube.
Figure 3 shows threaded or flanged connection of the split liquid level transducer in the open-hole vessel, wherein thread size or flange size are G 1 / 2 and DN20 respectively or customized.
Technical Parameters:Measuring range (FS) | 0~0.5m…200mH2O or 0~5KPa…2MPa |
Permissible overpressure | Two times of full-scale pressure |
Measuring media | The liquid compatible with 316 stainless steel ( Corrosion-proof type can be selected under special conditions) |
Overall accuracy | ±0.25%FS | ±0.4%FS | ±1%FS |
Long-term stability | Typical:±0.1%FS/year | Maximum:±0.2%FS/year |
Operating temperature range | Integrated: -20ºC~70ºC | Split (plug-in):-20ºC~80ºC |
Compensation temperature range | Integrated:-10ºC~55ºC | Split (plug-in):-10ºC~70ºC |
Zero-point temperature drift | Typical:±0.02%FS/ºC | Maximum:±0.05%FS/ºC |
Sensitivity temperature drift | Typical:±0.02%FS/ºC | Maximum:±0.05%FS/ºC |
Range of power supply | 12~36VDC(generally 24VDC) |
Signal output | 4~20mA/1~5VDC/ 0~5VDC |
Load resistance | ≤(U-12)/0.02Ω |
Structural material | Enclosure: stainless stee1 1Cr18Ni9Ni | Diaphragm: stainless steel 316L |
Sealing: fluoro rubber | Cable:Φ7.2mm special PVC cable |
Insulation resistance | 100MΩ,50VDC |
Lightning protection class | Class III lightning design(10000V/5kA);optional(20000V / 10000A)under special conditions |
Protection class | Enclosure protection class IP68 |
Safety and explosion protection | Ex iaII CT5 |
Response time | ≤2 ms |
Resolution | Infinitely small(theoretic),1/100000(normal) |
Thermal hysteresis | ±0.1%FS(typical value) |
Weight | Approx. 250g |
Ordering Information:JC621F | Industry Anti-Lightning Water Level Sensor |
| Measuring range | 0~X mH2O or 0~X KPa |
| Code | Structural form (maximum operating range) |
C1 | Integrated: 0~200mH2O |
C2 | Split: 0~10mH2O |
C3 | Plug-in: 0~4 mH2O |
| Code | Overall accuracy (linearity + repeatability + hysteresis) |
0 | 1.0%FS |
1 | 0.4%FS |
2 | 0.25%FS |
| Code | Signal output(standard power supply) |
A1 | 4~20mA (12~36V DC) |
V1 | 1~5V DC (12~36V DC) |
V2 | 0~5V DC (12~36V DC) |
S1 | RS485 (5~15V DC) |
| Code | Additional functions |
F1 | G1 1/2 male thread(split and plug-in) |
F2 | DN20 flange(split and plug-in) |
F0 | Special |
E | Intrinsically safe explosion-proof type Ex iaIICT5 |
R | Corrosion-proof type |
JC621F (0~10mH2O) -C1 -1 -A1 -E Industry Anti-Lightning Water Level Sensor |
Tips for Type Selection* The medium to be measured shall be compatible with the material contacting with the product. Meanwhile, the density of the medium to be measured during measurement shall be indicated (except for water).
* For battery supply feed, please indicate it in the order.
* As an additional function code for type selection, the code "E" for intrinsically safe explosion-proof type Ex ia II CT5 denotes that power source must be supplied via safety barrier.
* The length of cables shall be L = X m + 1m. Please indicate any extension (if needed) when placing an order. There are two kinds of cable materials. By virtue of its more flexibility and good wear resistance, polyurethane material can be selectively used. Where no special requirement is indicated, cables to be supplied shall be made of PVC material.
* The corresponding relationship of 1m water columns with pressure under standard conditions ( i.e. 4ºC, g = 9.80665 m / s2):1mH2O=0.1kgf/cm2(Kgf /cm2 )=9.8kPa(kPa)
* For other special requirements, please discuss with us and clearly indicate them in the order.
Address:
3rd Floor, Xuanyang Comprehensive Building, 155 Zhenxing Road, Fenghuang Industrial Park, Yanling Town, Nanjing, Jiangsu, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Auto, Motorcycle Parts & Accessories, Consumer Electronics, Electrical & Electronics, Industrial Equipment & Components, Instruments & Meters
Management System Certification:
ISO 9001
Company Introduction:
Established in 2006, Nanjing Helm Sci-tech Co., Ltd. (Nanjing Jiucheng technology Co., Ltd) is specialized in R&D and production of pressure measuring and controlling instruments. It has introduced the internationally advanced production technology, equipment and process as well as strict product quality standards and ODM cooperation concept to China, so as to manufacture and sell JC pressure / differential pressure / liquid level sensors and transducers in mainland China.
Our products have been fallen into six categories totaling hundreds of specifications in dozens of series. Main products include: High-accuracy Pressure Sensor, General-purpose Pressure transducer, Liquid Level transducer, Anti-lightning/Anti-corrosive Liquid Level transducer, Special Pressure transducer for Air Conditioner, Refrigeration and Compressor, Special Pressure transducer for Oilfield and Mining Well, Economical Pressure Sensor and transducer, Ceramic Capacitor Pressure transducer, Vacuum Pressure transducer, Sapphire Pressure transducer, Digital Pressure transducer, Micro Differential Pressure / Air Pressure transducer, Intelligent Digital Pressure Gauge, Intelligent Digital Pressure Switch, Anti-corrosive Pressure transducer, Anti-explosive Pressure transducer, Hygienically Flat-membrane Pressure transducer, High-temperature Pressure transducer, High-frequency Pressure transducer, Micro Pressure transducer, Integrated Temperature transducer, and Capacitance Pressure transducer.