Oilfield Flush Diaphragm Vacuum Pressure Sensor (JC623Y-06)

Product Details
Customization: Available
Measuring Medium: Gas Liquid Steam
Accuracy Grade: 0.1%
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
1001~2000 square meters
  • Oilfield Flush Diaphragm Vacuum Pressure Sensor (JC623Y-06)
  • Oilfield Flush Diaphragm Vacuum Pressure Sensor (JC623Y-06)
  • Oilfield Flush Diaphragm Vacuum Pressure Sensor (JC623Y-06)
  • Oilfield Flush Diaphragm Vacuum Pressure Sensor (JC623Y-06)
  • Oilfield Flush Diaphragm Vacuum Pressure Sensor (JC623Y-06)
  • Oilfield Flush Diaphragm Vacuum Pressure Sensor (JC623Y-06)
Find Similar Products

Basic Info.

Model NO.
JC623Y-06
Pressure range
-100kpa ~220MPa
IP Rating
IP67
Certification
CE
Customized
Customized
Transport Package
Standard Exporting Carton
Trademark
JC
Origin
Nanjing, China
Production Capacity
5000 Pieces Per Month

Product Description


JC623Y-06 Oilfield Flush Diaphragm Vacuum Pressure Sensor Overview:

JC623Y-06 oilfield flush diaphragm vacuum pressure sensor is specially designed and manufactured for very harsh environment such as blocking pressure-guided holes by drilling mud as well as strong vibration during oilfield drilling and well logging. This transducer takes European advanced thin/thick sputtered film ceramic pressure sensors as sensitive elements for integration with electronic circuits. This type of pressure transducers is of fully stainless steel cylindrical structure and easy to operate. It is specially applicable for such viscous, easily blocked and strongly vibrating industrial sites as oil field logging, pharmacy and textile manufacturing, etc.. Moreover, it has achieved desirable application effects in oil fields at home.

JC623Y-06 Oilfield Flush Diaphragm Vacuum Pressure Sensor Features:
* High temperature and high pressure
* High accuracy and high stability
* Vibration, impact and corrosion resistance and fully stainless steel structure
* Small volume, light weight, and direct process installation

JC623Y-06 Oilfield Flush Diaphragm Vacuum Pressure Sensor Application:
* Subsurface equipment for petroleum
* Airspace and aerospace
* Pharmaceutical, biochemical and fermentation systems
* Other automatic control and detection systems


Technical Parameters:
Measuring range -100KPa~ 0~100KPa …220 MPa
Overload capacity 2 times of full-scale pressure(wherein the overpressure 
of more than 100MPa is 1.1 times of full-scale pressure)
Pressure type Gauge pressure or absolute pressure
Measuring media The gas or liquid compatible with 316 stainless steel
Range of power supply 12~36VDC(generally 24VDC)
Signal output 4~20mA / 1~5VDC / 0~5VDC / 0.5~4.5VDC
Accuracy  (nonlinearity + hysteresis + repeatability) ±0.1%FS ±0.25%FS ±0.4%FS
Long-term stability ±0.1%FS/year
Range of operating temperature   -40~+120ºC
Range of compensation temperature -20~+85ºC
Temperature performance Zero temperature coefficient:≤±0.02%FS/ºC
Sensitivity temperature coefficient:≤±0.02%FS/ºC
Thermal hysteresis ±0.1%FS(typical value)
Liquid contacting material Diaphragm:17-4PN or   AL2O3
Response time ≤2ms
Load resistance ≤(U-12)/0.02 Ω
Insulation resistance 100MΩ,500 VDC
Enclosure protection class Plug-in type(IP65); cable type(IP67)
Safety and explosion protection Ex iaII CT5
Weight Approx.0.25 kg
Vibration error ≤±0.1%FS(Axes X,Y,Z,200Hz/g)

Ordering Information:
JC623Y-06 Oilfield Flush Diaphragm Vacuum Pressure Sensor
  Pressure type Gauge pressure (G may not be indicated);absolute pressure(A)
  Range ( 0~ X MPa)Measuring range
  Code Overall accuracy (linearity + repeatability + hysteresis)
1  ±0.4%FS
2  ±0.25%FS
3 ±0.1%FS
  Code  Signal output
A1 4~20mA  
V1 1~5V DC  
V2 0~5V DC  
V3 0.5~4.5V DC
  Code Additional functions
F1 M20x1.5 external thread
F2 G1/4 external thread
F3 M24x1.5 external thread
F0 Special
W1 Cable type(IP67,2m)
W2 HSM socket type(IP65,DIN43650)
W3 Aviation plug type(IP65)
P Flush diaphragm type
E Intrinsically safe explosion-proof type Ex iaIICT5
JC623Y-06  (0~20MPa)   -1     -A1    -F1    -W2      Oilfield Flush Diaphragm Vacuum Pressure Sensor

Tips for Type Selection
* The medium to be measured shall be compatible with the material contacting with the product.
* As an additional function code for type selection, the code "E" for intrinsically safe explosion-proof type Ex ia II CT5 denotes that power source must be supplied via safety barrier.
* For other special requirements, please discuss with us and clearly indicate them in the order.



About Jiucheng

Qualification and Certificate:



Product Packaging:
We choose cartons and protective pads that can be recycled. This will maximize the protection of our products from damage during transportation.


Product Transportation:
We only choose the global express service providers. We will deliver the goods to you at the most efficient speed.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier