Customization: | Available |
---|---|
Type: | Normal Pressure Transmitter |
Structure Type: | Diffused Silicon Pressure Transmitter |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Measuring Range | 0~100Pa…100KPa | |
Overload Capability | 1.5~2 times full-scale pressure | |
Burst Pressure | 4xFS | |
Durability | >1×107 cycle(P:0~FS) | |
Pressure Type | Gauge / Absolute | |
Measuring medium | Dry clean gas compatible with 304 stainless steel | |
Response time | ≤4ms | |
Resolution | Minimum. 0.5Pa | |
Accuracy (linear,hysteresis, repeatability) | Typical:±0.5%FS Typical:±1%FS(below 250Pa) |
Maximum:±1%FS Maximum:±2%FS(below 250Pa) |
Long-term stability | Typical:±0.2%FS/year | Maximum:±0.3%FS/year |
Zero temperature drift | Typical:±0.02%FS/ºC | Maximum:±0.05%FS/ºC |
Sensitivity temperature drift | Typical:±0.02%FS/ºC | Maximum:±0.05%FS/ºC |
Medium Temperature | -40~100ºC |
Ambient Temperature | -40~85ºC |
Compensation Temperature | -20~80ºC |
Vibration resistance | 10g IEC 60068-2-6 |
Impact resistance | 100g/1ms IEC 60068-2-27 |
EMC- launch | EN61000-6-3 |
EMC- anti-interference | EN61000-6-2 |
Insulation resistance | >100MΩ/100V |
Shell Protection | Plug type(IP65); Cable type(IP67) Compliance IEC 60529 standard |
Certification | CE |
Code | Standard signal (with short circuit protection) | Supply voltage with polarity protection | Power supply- Current | Load(R) | Output Impendence |
A1 | 4~20mA | DC 9~30V | Max.25mA | R≤(U-9)/0.02Ω | |
V1 | 1~5V DC | DC 9~30V | 8mA | R≥50kΩ | <2kΩ |
V2 | 0~5 V DC | DC 9~30V | 8mA | R≥50kΩ | <2kΩ |
V3 | 0.5~4.5V DC | DC 9~30V | 8mA | R≥50kΩ | <2kΩ |
V4 | 0.5~4.5V DC | DC 5±0.25V | 8mA | R≥50kΩ | <2kΩ |
Interface and housing | Stainless Steel 304L |
O-ring | Silicone Rubber |
Sensor Diaphragm | Silicon wafer(measured dry ,dust-free, non-corrosive or weakly corrosive, clean gas) |
Weight | Approx.150g |
JC30 | G | 01KN | A1 | F2 | W2 |
Model | Pressure type | Pressure Range | Output | Mounting thread | Electrical connections |
JC30
|
G=Gauge or wind/air pressure D=Differential Pressure |
002C= ±200Pa G/D 005C= ±500Pa G/D 01KC= ±1KPa G/D 02KC= ±2KPa G/D 05KC= ±5KPa G/D 10KC= ±10KPa G/D 005N= -500Pa G/D 01KN= -1KPa G/D 02KN= -2KPa G/D 05KN= -5KPa G/D 10KN= -10KPa G/D 20KN= -20KPa G/D 002P= 200Pa G/D 005P= 500Pa G/D 01KP=1KPa G/D 02KP= 2KPa G/D 05KP= 5KPa G/D 10KP= 10KPa G/D 20KP= 20KPa G/D 40KP= 40KPa G/D 001B= 100KPa G/D |
A1=4~20mA V1=1~5V V2=0~5V V3=0.5~4.5V V4=0.5~4.5V/5V |
F1=M20x1.5male F2=G1/4male F5=Ф8 gas nozzle F0= Customize |
W1=Straight Out 1m W2=A type HSM plug W3=M12 corner out 1m W4=M12 Straight Out 1m |
Model example: JC30G01KNA1F2W3
(JC30 Air Pressure/ Micro Differential Pressure Transmitter; Range 0~1MPa Gauge; Output 4~20mA; Accuracy 0.5% typical; Power Supply 9~30VDC;Pressure Connection G1/4 male thread; Electrical Connection M12 corner out 1m; Selection Remarks: The range meter 01KP=1KPa G/D G indicates the gauge pressure or wind/air pressure, which is the pressure difference with the atmosphere, that is, the wind pressure measurement of a single pressure port, D is the differential pressure measurement, measuring the pressure difference between the two pressure ports. Use the B-copper joint in the outline drawing to connect the negative pressure port, as shown in the outline drawing.
Remarks: It can be customized if the order quantity exceeds a certain amount. Please contact the salesengineers for details.