Customization: | Available |
---|---|
Type: | Piezoresistive Pressure Sensor |
Component: | Mechanical Structure Type |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Measuring range | 0~10KPa...2 MPa | ||
Fullscale range | 10~50KPa | ||
Positive permissible overpressure | ≥3 times of full scale,≤2MPa | ||
Negative permissible overpressure | 2 times of full scale,≤2MPa | ||
Maximun static pressure | ≤20MPa | ||
Overall accuracy(nonlinearity + repeatability+hysteresis) |
±0.1%FS | ±0.25%FS | ±0.5%FS |
Zero temperature error | ±0.02%FS/ºC(typical) ±0.05%FS/ºC(maximum) | ||
Sensitivity temperature error | ±0.02%FS/ºC(typical) ±0.05%FS/ºC(maximum) | ||
Influence of static pressure | ±0.05%FS/100KPa | ||
Operating temperature | -10~80ºC | ||
Compensation temperature | -10~50ºC | ||
Long-term stability | ±0.3%FS/year(≤200kPa) ±0.1%FS/year(≥200kPa) | ||
Range of power supply | 12~36V DC(generally 24V DC) | ||
Output signal | TwO-wire 4~20mA DC,three-wire 0/1~5V DC | ||
Response time | ≤2 ms | ||
Insulation resistance | 100MΩ,500VDC | ||
nfluence of vibration | ≤1%change after vibration at 3gRMS 30~2000Hz | ||
Impact | ≤1%change after impact of 100g for 10ms | ||
Service life | 1×108pressure cycles | ||
Medium | The liquid or gas adapting to structural material | ||
Enclosure protection class | Plug-in type(IP65);cable type(IP67) | ||
Safety and explosion protection | Ex ia ll CT5(intrinsically safe explosion-proof type) | ||
Weight | Approx 0.35kg | ||
Thermal hysteresis | ±0.1%FS(typical value) | ||
Enclosure protection class | Plug-in type(IP65);cable type(IP67) |
JC631 Differential Pressure Transducer | |||||
Range | Measuring range(0~X KPa or MPa) | ||||
Code | Overall accuracy (linearity +repeatability+hysteresis) | ||||
1 | ±0.5%FS | ||||
2 | ±0.25%FS | ||||
3 | ±0.1%FS | ||||
Code | Signal output (standard power supply) | ||||
A1 | 4~20mA(12~36V DC) | ||||
V1 | 1~5V DC(12~36V DC) | ||||
V2 | 0~5V DC(12~36V DC) | ||||
V3 | 0.5~4.5V DC(12~36V DC) | ||||
Code | Additional functions | ||||
F1 | M20x1.5 male thread | ||||
F2 | G1/4 male thread | ||||
F0 | Special | ||||
W1 | Cable type(IP67,2m) | ||||
W2 | Socket type(IP65,DIN43650) | ||||
E | Intrinsically safe explosion-proof type Ex iallCT6 | ||||
JC631 (0~50KPa)-1-A1-F2-W1 Differential Pressure Transducer |